To ensure that components with small lead diameters will be accurately sensed while maintaining the ability to detect missing components, the overlap of the refire housing to the component support must be set.
Prerequisites:

Machine main power is on, machine is palmed down. To adjust the feeder refire assembly, perform the following procedure.

1.Loosen the refire housing screws. Adjust the refire housing until the refire contact is flush to within .010 inch (0,25mm) overlap with the edge of the component support section of the cutter holder. Refer to the illustration.

2.Loosen the screws and alternately adjust the position of the feeder cover and the refire housing until the results described in step 1 are achieved. Ensure that all screws are tight when the setup is completed.

 

End of procedure.